78
The test is finished successfully.
The test is stopped by the user.
The test did not finish.
In the first condition, the tool will display an information screen as
The operation was performed correctly. Put the vehicle on a
vehicle lift and check that the rear wheels are locked. Check that
the 'Electric parking brake on' message is display on the control
panel and that the LED illuminates on the control panel.
In the second condition, the tool will display an information screen
as Operation of the actuator test was stopped by the user. Press
Cancel' to go back to the list of possible operations.
In the third condition, the tool will display an information screen as
The actuator test did not finish operating. Please perform the
following check: Read the faults to resolve any possible faults
relating to the electric motor or to the cables.
IMPORTANT: Make sure that the components to be tested are
not physically damaged and are well assembled.
WARNING: Please stop repairing the components to be tested
before the test starts and keep a certain distance during the test.
8.3. ABS Maintenance
In the System menu (Figure 8.2), use UP/DOWN button to select
ABS to do ABS maintenance. The scan tool displays as below:
Figure 8.20
Diag. Menu
6. Read Codes
7. Erase Codes
8. Live Data
9. Active Test
10. ECU Information
6. Special Function